Vacuum Blood Collection Tubes and Needles

Clot-Activator-Vacuum-tubes

Clot Activator

Pro-coagulation Tube is used in blood collection and storage for biochemistry and immunology tests.

Its main merit is that it’s suitable for a wide range of operation, fast in coagulation, and free from both secondary separation of fibrin protein and the cracking of blood corpuscle.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Red Ø13x75mm
Ø13x100ml
4ml, 5ml
6ml, 7ml
±10% 1800pcs/ctn AcCuvet / eVac Glass/Pet
yellow

Gel + Clot

Gel & Clot Activator Tube is used for clinical biochemistry and immunology. Inside the tube there is a barrier gel present at the bottom, which is a pure substance, very stable in physical and chemical features. After centrifugation, the barrier can effectively separate the serum from fibrin and cells, while preventing substance exchange between blood cell and serum. As a result, it can keep biochemical characters and chemical components of serum unchanged for a long time.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Yellow Ø13x75mm
Ø13x100ml
4ml, 5ml
6ml, 7ml
±10% 1800pcs/ctn AcCuvet / eVac Glass/Pet
grey

Fluoride

Glucose Tube is used in blood collection and anticoagulation for the analyses such as blood sugar, sugar tolerance, anti-alkali haemoglobin and sugar water. It is available with different additives, sodium fluoride/potassium oxalate and sodium fluoride/ammonium fluoride/potassium oxalate. Now we use inhibitor for glucolysis. Owing to the first use of special stabilizer and surface treatment inside the tube,glucose tube successfully solves the unavoidable hemolysis and prevents the occurrence of insoluble and anti-coagulant substances.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Gray Ø13x75mm
Ø13x100ml
4ml, 5ml
6ml, 7ml
≤5% 1800pcs/ctn AcCuvet / eVac Glass/Pet
green

Lithium Heparin

Heparin Tube is used in blood collection and anti-coagulation not only for routine clinical biochemistry tests and emergency biochemistry tests but also for some test items in blood rheology. It is coated with lithium heparin. The anticoagulant heparin activates antithrombins,thus blocking the coagulation cascade and producing a whole blood/ plasma sample instead of clotted blood plus serum. Soon after the sampling, turn the tube 180°upside down,shaking and mixing 5-6 times.Heparin Anticoagulation Blood sample should be used within 6 hours after sampling, otherwise, the blood will coagulate again.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Green Ø13x75mm
Ø13x100ml
4ml, 5ml
6ml, 7ml
±10% 1800pcs/ctn AcCuvet / eVac Glass/Pet
green

Sodium Heparin

Heparin Tube is used in blood collection and anti-coagulation not only for routine clinical biochemistry tests and emergency biochemistry tests but also for some test items in blood rheology. It is coated with sodium heparin. The anticoagulant heparin activates antithrombins,thus blocking the coagulation cascade and producing a whole blood/ plasma sample instead of clotted blood plus serum. Soon after the sampling, turn the tube 180°upside down,shaking and mixing 5-6 times.Heparin Anticoagulation Blood sample should be used within 6 hours after sampling, otherwise, the blood will coagulate again.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Green Ø13x75mm
Ø13x100ml
4ml, 5ml
6ml, 7ml
±10% 1800pcs/ctn AcCuvet / eVac Glass/Pet
purple

EDTA Tube

EDTA Tube is widely used in clinical haematology as well as various kinds of blood cell test instruments. It makes use of EDTA K2/ EDTA K3 as anticoagulant. Meanwhile, it offers a comprehensive protection for blood cell, especially for protecting the blood platelet, so that it can effectively stop the gathering of blood platelet and makes the form and volume of blood cell uninfluenced in a long time. EDTA tube can be used in direct sampling analyzers without actually being opened.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Purple Ø13x75mm,
Ø13x100ml
K3 – 2ml, 3ml,
K2 -2ml
±10% 1800pcs/ctn AcCuvet / eVac Glass/Pet
DSC_3129

Sodium Citrate 3.2% 1.8ml

Citrate Tube is mainly used for the test of blood coagulation mechanism. The tube inner walls are specially processed for preventing the sticking and hemolysis.

It is filled with buffered tri-sodium citrate solution.The choice of the concentration depends upon the policies of the laboratories.The mixing ratio is 1 part citrate to 9 parts blood with the advantage of high accurate blood-to-additive ratio. It can provide an excellent condition for the test of PT and APTT values.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Blue 13x75mm 1.8ml ≤5% 1800pcs/ctn AcCuvet / eVac Glass/Pet
esr-tube

ESR Tube

ESR Tube is used in blood collection and anticoagulation for sedimentation rate test. It contains a 3.8% buffered tri-sodium citrate solution (0.129mol/l) with the mixing ratio of 1 part citrate solution to 4 parts blood. ESR measurement refers to the Westergren method. Sampling the blood dosage as required to ensuring the test accuracy.

Product Description

Color Code Specifications General Sampling Dosage Maximum Vacuum Tolerance Packing Brand Material
Black Ø8x120mm 1.28ml ≤5% 1200pcs/ctn AcCuvet / eVac Glass
black

Sodium Citrate 3.8% 1.6ml

Tube is used in blood collection and anticoagulation for sedimentation rate test.ESR measurement refers to the Westergren method.
Mixing requirement: After blood collection turn the tube upside down with 180 degree and shake it 5-8 times carefully of insoluble and anti-coagulant substances.

Product Description

Color Code Specifications Volume Maximum Vacuum Tolerance Packing Brand Material
Black Ø13 x75mm,Ø13 x100mm 1.6ml ≤5% 1800pcs/ctn AcCuvet / eVac Glass/Pet
needle

Anti Back Flow

Anti backflow needles allow healthcare workers immediate visual confirmation of a successful venipuncture

Product Description

  • Product Structure: protector cap ,needle cannula ,rubber with needle cannula.
  • Blood collection needle is used together with vacuum blood collection tubes and holder to collect blood from human body.
  • It provide fast and convenient blood multiple sampling by single puncture.
  • High quality ultra-sharp needle assure atraumatic insertion and painless penetration
Gauge Length Packsize Box
22G 1″ 100 18*100
Multi-Draw

Multi Draw

Multi-sample needles permit several samples to be taken with a single puncture – Sharp & smooth edges make penetration painless for patients and provides easy connection to rubber stoppers

Gauge Length Packsize Box
21G, 22G 1, 1.5″ 100 40*100
Tourniquet-belts

Tourniquet Belt

Features

  • High functionality
  • Sturdy construction
  • Durable
  • Elegant design
  • Easy to use
  • Economical Price
  • High strength
  • Tear resistance
  • High performance
  • Precisely designed

50 nos in a pack

HOLDER

Holders

Multi-sample needle holder is made of unbreakable polypropylene (PP) and is designed and priced to be disposable. The holder completes the blood collection assembly when combined with appropriate needles and evacuated blood collection tubes. Use it once and discard it with the needle attached. This eliminates the hazards associated with reusable needle holders